NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster
NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster
NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster
NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster
NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster

NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster

0.0
0 sold.
Minimum quantity is: 1 pcs

Price from:

46,243,400 so'm

Guaranteed delivery time

If we are 45 days late, you will receive your order for free. More details

Always in touch with you

We will answer any questions every day.

Secure payment in a convenient way

We will accept payment by any card

NLT-30N Adhesion Tester Pharmacopoeia part IV adhesion plaster plaster

About the product

Characteristic

Origin

Jinan

Product Use

It is suitable for the adhesion test of all kinds of plaster, plaster, band-aid, medical tape, etc. directly applied to body materials.

Item No.

NLT-30N

Type

Paste viscosity test

Brand

Chen Chi

Model

NLT-30N

Import or not

No

Customized processing

Yes

Order Number

NLT-30N

Description

NLT-30N 黏着力测试仪

未标22222222题-2

未标题-1

 未标22222222题-2

产品简介

 

NLT-30N黏着力测试仪 适用于各类贴膏剂、膏药、创可贴、医用胶带等等直接贴敷身体材料的黏着力测试。贴膏剂系指将原料药物与适宜的基质制成裔状物、涂布于背衬材料上供皮肤贴敷、可产生全身性或局部作用的一种薄片状制剂。附力大小直接影响药品的安全性和有效性,应进行必要的控制。粘着力表示贴膏剂、贴剂的粘性表面与皮肤附着后对皮肤产生的粘附力。

 

产品特点:

1.系统采用微电脑控制,搭配液晶显示屏幕和PVC操作面板,方便用户快速、直观的查看检测数据和结果

2.配备多种规格力值传感器可选,支持剥离和拉伸双重试验模式可选;

3.试验速度无极可调,满足不同测试条件的要求;

4.仪器具有测试数据最大值、最小值、和平均值统计分析功能;

5.限位保护、过载保护、自动清零、以及故障提示等智能配置,保证用户的操作安全;

6.配备微型打印机和RS232通用数据接口,方便数据输出和传递

参照标准

该仪器符合标准:2020版药典第四部

技术参数:

指标

参数

试验力

3、5、10、30、50、100N可选

标配试验力

30N

操作方式

专业黏着力测控软件

试验方法

黏着力

测量范围

最大试验力的0.5%—100%

精度级别

±0.5%

试验力准确度

优于示值的±0.5%

变形显示误差

优于示值的±0.5%

试验力分辨率

1mN

位移分辨率

0.001mm

变形准确度

优于±0.5%

液晶显示内容

试验力、位移、峰值、运行状态、运行速度等

无级调速

采用步进电机及控制系统

驱动方式

步进电机,滚珠丝杠传动

调速范围

1mm/min~~650 mm/min

试验行程

300mm(不含夹具)

试验保护功能

过载保护、漏电保护、限位保护

  

AC 220V 50Hz

外形尺寸

主机:600mm(L)×300mm(W)×250mm(H)

   

20Kg

 

产品配置

标准配置:主机、微型打印机、黏着力测试工装、电源线、技术文件等;

件:计算机、专业软件、通信电缆、非标测试附件;

注:辰驰仪器始终致力于产品性能和功能的创新及改进,基于该原因,产品技术规格、外观亦会相应改变,上述情况恕不另行通知。本公司保留修改权与最终解释权。

Characters

Properties

Origin

Jinan

Product Use

It is suitable for the adhesion test of all kinds of plaster, plaster, band-aid, medical tape, etc. directly applied to body materials.

Item No.

NLT-30N

Type

Paste viscosity test

Description

NLT-30N 黏着力测试仪

未标22222222题-2

未标题-1

 未标22222222题-2

产品简介

 

NLT-30N黏着力测试仪 适用于各类贴膏剂、膏药、创可贴、医用胶带等等直接贴敷身体材料的黏着力测试。贴膏剂系指将原料药物与适宜的基质制成裔状物、涂布于背衬材料上供皮肤贴敷、可产生全身性或局部作用的一种薄片状制剂。附力大小直接影响药品的安全性和有效性,应进行必要的控制。粘着力表示贴膏剂、贴剂的粘性表面与皮肤附着后对皮肤产生的粘附力。

 

产品特点:

1.系统采用微电脑控制,搭配液晶显示屏幕和PVC操作面板,方便用户快速、直观的查看检测数据和结果

2.配备多种规格力值传感器可选,支持剥离和拉伸双重试验模式可选;

3.试验速度无极可调,满足不同测试条件的要求;

4.仪器具有测试数据最大值、最小值、和平均值统计分析功能;

5.限位保护、过载保护、自动清零、以及故障提示等智能配置,保证用户的操作安全;

6.配备微型打印机和RS232通用数据接口,方便数据输出和传递

参照标准

该仪器符合标准:2020版药典第四部

技术参数:

指标

参数

试验力

3、5、10、30、50、100N可选

标配试验力

30N

操作方式

专业黏着力测控软件

试验方法

黏着力

测量范围

最大试验力的0.5%—100%

精度级别

±0.5%

试验力准确度

优于示值的±0.5%

变形显示误差

优于示值的±0.5%

试验力分辨率

1mN

位移分辨率

0.001mm

变形准确度

优于±0.5%

液晶显示内容

试验力、位移、峰值、运行状态、运行速度等

无级调速

采用步进电机及控制系统

驱动方式

步进电机,滚珠丝杠传动

调速范围

1mm/min~~650 mm/min

试验行程

300mm(不含夹具)

试验保护功能

过载保护、漏电保护、限位保护

  

AC 220V 50Hz

外形尺寸

主机:600mm(L)×300mm(W)×250mm(H)

   

20Kg

 

产品配置

标准配置:主机、微型打印机、黏着力测试工装、电源线、技术文件等;

件:计算机、专业软件、通信电缆、非标测试附件;

注:辰驰仪器始终致力于产品性能和功能的创新及改进,基于该原因,产品技术规格、外观亦会相应改变,上述情况恕不另行通知。本公司保留修改权与最终解释权。

From this seller

View all